Diagnosing Driver Issues

Last published : Oct 07, 2026
The following section gives some information about reading logs related to Drivers, and solutions to some common issues.
Related information

Driver Cannot Log In to Manager

When a Driver cannot log in to a Manager, messages similar to the following message appear in the Manager log:
LoginPlugin Can't log in to PrivateBrokerConnection
LoginPlugin Failed login on http://162.60.27.152:8000/livecluster/director/PublicDriverChannel so trying next. Error:
File not found: http://162.60.27.152:8000/livecluster/director/PublicDriverChannel
When this happens, try the following:
  • Ping and telnet to the Manager and port number to test network connectivity.
  • Check the username, password, and Director values in the driver.properties file or values coded in application.
  • If using SSL, make sure the certificate is valid.

Client Timeout Issues

You might see timeout error messages in the Driver log similar to the following message:
java.io.IOException: Unexpected exception while reading data from http://172.24.68.49:1667/ds-6353115010724789381/job.tasklet: com.livecluster.util.threadpool.TimeoutException: Thread DefaultPool-6:
http://172.24.68.49:1667/ds-6353115010724 789381/job.tasklet timed out
The Client Timeoutsetting allows for the Driver to log back in after logging off due to temporary network issues, without interrupting Services.
Go to Admin > System Admin > Manager Configuration > Communication. Under the HTTP Connectionsheading, you can increase read and write timeout values for Drivers.
Also, the Driver must not fail over to another Broker too quickly. This is set in DSBrokerTimeout in the driver.properties file. The default is 300 seconds, or 5 minutes.
To ensure your tasks are not lost in the event of Broker failure, perform the following actiond:
  1. GNavigate to Admin > System Admin > Manager Configuration > Engines and Clients.
  2. Under the Engine Loginheading for a period of time longer than the Client Timeout Minuteson the same page, under the Client Managementheading, set Engine Timeout Minutesat.
    For example, if Client Timeout Minutesis set to 5 minutes, a good number for Engine Timeout Minutesis 8 minutes. Note that changes to this value are only applied at the next Engine log in.

Manager Turning Away Clients

By default, Drivers are turned away if there is a version mismatch between Client and Manager. A message similar to the following message appears in the Manager log:
[BrokerLoginManager] Turning away client: Client module version mismatch: ClientJavaVersion version: 7.0.0: should be 7.1.0.
To override this, go to Admin > System Admin > Manager Configuration > Admin, and under the Version Managementheading, set Allow Driver Version Mismatchto true until the Client can be upgraded.