Prior to Upgrade
-
If you have any UNIX Engines that share a common installation directory, you must migrate those installations to a local directory. A shared install point is no longer supported.
-
To enable programmatic version control, ensure that
gridLibraryStrictVersioningis set tofalse. -
If you have a Linux64 Engine, for upgrade from all versions earlier than 7.0.0\_hotfix08, you must perform the following steps:
-
Stop the server.
-
As a best practice, take a backup of the existing
engine.shfile. -
Replace the
engine.shfile from theengineScriptUpdatefolder todatasynapse/manager/webapps/livecluster/engineUpdate/linux64/ and datasynapse/manager-data/engineUpdate/linux64/folder. -
Start the server.
-
Let the Engines log in and then restart the Engine Daemon.
-
Stop the server.
-
Upgrade the server.
**Note:**In case of Grid Architecture, perform the steps from step a to step g on the Primary Director.
-
Check the list of changes in the release notes for any other issues that might affect you.